Fitted two peaks in each power spectrum using a Lorentzian with a local linear baseline. Intensity is the Lorentzian height above that baseline. The CSV contains each peak’s fitted intensity and position \(x_c\), with fit uncertainties.

The allometric model was \(y=aP^b\), fitted in log space. The reported ± values are the slope’s standard errors.

| Peak | Intensity exponent \(b\) | Position exponent \(b\) |
|---|---:|---:|
| Peak 1 (~1.32–1.34 eV) | 0.9233 ± 0.0121 | 0.00447 ± 0.00008 |
| Peak 2 (~1.53 eV) | 0.8357 ± 0.0309 | 0.00195 ± 0.00029 |

Files: [intensity plot](<<BENCH>/raw/commercial/luna-high/bench/t-pl/run-04/peak_intensity_vs_power.png>), [position plot](<<BENCH>/raw/commercial/luna-high/bench/t-pl/run-04/peak_position_vs_power.png>), [fitted values for every power](<<BENCH>/raw/commercial/luna-high/bench/t-pl/run-04/lorentzian_peak_fits.csv>), [analysis script](<<BENCH>/raw/commercial/luna-high/bench/t-pl/run-04/analyze_spectra.py>).

RESULT: b = 0.9233 ± 0.0121