I fitted two resolved Lorentzian bands in each of the 15 spectra, using peak height above a local linear background as intensity. The upper edge of the measured range rises without turning over, so it does not provide a complete peak to fit.

The plots show the measured values and allometric fits:

- [Peak intensity vs. power](<<BENCH>/raw/commercial/luna-high/bench/t-pl/run-16/peak_intensity_vs_power.png>)
- [Peak position vs. power](<<BENCH>/raw/commercial/luna-high/bench/t-pl/run-16/peak_position_vs_power.png>)

The fitted peak values are in [lorentzian_peak_fits.csv](<<BENCH>/raw/commercial/luna-high/bench/t-pl/run-16/lorentzian_peak_fits.csv>). Allometric exponents \(b\) (with log–log regression standard errors) are: intensity, Band 1 = 0.9264 ± 0.0134 and Band 2 = 0.8193 ± 0.0379; peak position, Band 1 = 0.004445 ± 0.000105 and Band 2 = 0.001970 ± 0.000378. The requested result is for the dominant Band 1 intensity.

RESULT: b = 0.9264 ± 0.0134